IG Electrocardiograph EKG Series 3CH
Our 3-channel ECG has an ergonomic, lightweight design and is easy to use in hospitals, doctors’ offices and even ambulances.
- Display
- 7″ LCD
- Leads
- 12 simultaneous
- Battery
- Up to 3 h
- Patients
- Adult, paediatric, neonatal
Our 3-channel ECG has an ergonomic, lightweight design and is easy to use in hospitals, doctors’ offices and even ambulances. Its diagnostic applications check for cardiac abnormalities, detect chest pain with acute myocardial ischaemia and myocardial infarction, and evaluate arrhythmias. Suitable for adults, paediatrics and neonates.
- 01Ergonomic and lightweightEasy to use in hospitals, doctors’ offices and ambulances
- 02Automatic interpretationMinnesota code with CSE and AHA database support
- 03Long-term recording30–300 s recording with rhythm analysis
Included in the standard configuration. Ask us about options and customization.
- 017″ LCD screen
- 02Very high sensitivity and specificity of QRS detection
- 03Unique ECG data acquisition module
- 04Four sensitivity levels
- 05Independent lead wires
- 06Data formatsPDF, JPEG, DICOM, XML
- 07Alphanumeric keyboard
- 08StorageUSB, SD card, internal memory
- 09Built-in LANand Wi-Fi option
- 10Automatic and manual recording
- 11Long-term recordingup to 300 s
- 12On-screen operation guide
- 13Rechargeable batteryfor up to 3 h working time
- 14Interpretation by Minnesota codewith CSE and AHA database support
As published by the manufacturer. Configurations can vary by market; confirm with our team before ordering.
Request datasheet| Patient cable | Standard 12-lead cable, defibrillation-proof |
|---|---|
| Lead standard | 12 leads, simultaneous acquisition |
| Display | 7″ LCD; shows instrument status, time and heart rate |
| Long-term recording | 30 s – 300 s, with rhythm analysis |
| Measurement parameters | Ventricular rate, PR interval, QRS duration, QT/QTc interval, P/QRS/T axis, RV5/SV1 amplitude and RV5+SV1 amplitude |
| Filters | AC, drift and myoelectric filters |
| CMRR | > 89 dB |
| Input impedance | > 50 MΩ |
| Frequency response | 0.05 – 250 Hz |
| Patient leakage current | < 10 µA |
| Input circuit current | ≤ 0.1 µA |
| Time constant | ≥ 3.2 s |
| Sensitivity | 2.5, 5, 10, 20 mm/mV |
| Paper speed | 5, 6.25, 10, 12.5, 25, 50 mm/s |
| Recording paper | 80 mm roll; 80 mm × 90 mm × 300 p fan-fold |
| Operation modes | Automatic, manual, rhythm |
| Calibration | 1 mV, zeroing reset, automatic baseline correction |
| Battery | DC 14.8 V rechargeable Li-ion, 3 h working time |
| Safety level | IEC Class II, Type CF |
| Power supply | AC 100–240 V, 50/60 Hz, 110 VA |
| Operating environment | +5 °C to +40 °C; relative humidity ≤ 95 % (non-condensing); air pressure 86–106 kPa |
| Data memory | Internal memory up to 3000 files; SD card for mass storage; USB flash drive for data transfer |